Non shrink grout astm c 1107 pdf

It can be mixed to a plastic, flowable or fluid consistency based upon what the particular needs are on the jobsite. Packaging and yield five star grout is packaged in heavyduty, polyethylene lined bags and is available in 50 lb. Corps of engineers specification for nonshrink grout. Astm c 1107c 1107m08 standard specification for packaged. Aug 03, 2019 astm c1107 pdf 30 products find astm c products and abstract using the buildsite database. Rapid hardening cementitious materials for concrete repairs 5. With the release of the 2005 edition of astm standards for concrete and aggregates, a revision was made to astm c1107 the standard specification for packaged dry, hydrauliccement nonshrink grout. Precision nonshrink construction grout is nonshrink and nonmetallic. Crdc621 corps of engineers specification for nonshrink. Astm c1107 specification for packaged dry, hydrauliccement grout nonshrinkable c. Nonshrink precision grout is a high strength, nonmetallic, nonshrink grout designed for a variety of grouting and anchoring applications. Product complies with applicable portions of astm c928 r3 when tested at the conditions specified in table 2. Provides a high strength, non shrink grout for a broad range of general construction projects. It will exhibit slight expansion prior to initial set in normal working temperatures.

Astm c1107 c1107m standard specification for packaged dry, hydrauliccement grout nonshrink. Specification for non shrink grout grades a, b and c expansion astm c 1090. Astm c1107 standard specification for packaged dry, hydraulic. This specification covers packaged dry, hydraulic cement grout nonshrink intended for use under applied load where a. Grout shall conform to astm c1107 and the properties described in this special specification. Astm c1107 specification for packaged dry, hydrauliccement grout non shrinkable c. Nonshrink construction grout 50lb concrete mix in the. Quikrete nonshrink precision grout complies with the physical requirements of astm c1107 and crd 621 when tested at 72 degrees f 22 degrees c. Masterflow 928 grout is a hydraulic cementbased mineral aggregate nonshrink grout.

This specification covers packaged dry, hydraulic cement grout nonshrink. Can be mixed at a wide range of consistencies hardens free of bleeding when properly placed. Submittal data sc multipurpose grout nonshrink, non. Crd c 621 grades a, b, c astm c 1107 grades a, b, c specification for non shrink grout astm c 827 1107 advantage grout yielded a controlled positive expansion test results. Always add water to mixer first, then slowly add powder. Find submittalready datasheets, sds, specs, icces reports. Army corps of engineers, concrete research division crd. An astm designation number identifies a unique version of an astm standard. Nonmetallic 3 nonshrink grouting product highlights concretemeets astm c 1107 requirements at a fluid consistency 2030 second flow wide application temperature range of 50 to 85 f 10 to 29 c. Crdc621 corps of engineers specification for non shrink grout document center. Conforms to astm c 827 and astm c 1090 positive expansion. Change in height at early ages of cylindrical specimens of cementitious mixtures. Features and benefits interiorexterior pumpable flowable high strength non shrink non corrosive non metallic meets corps of engineers specification crd c 621 meets or exceeds astm c 1107 uses.

Installation instructions for use as a grout mixing quikrete fastset nonshrink grout should be mechanically mixed for a minimum of 3 minutes. Active standard astm c1107 c1107m developed by subcommittee. Modifications apply only when testing material according to article 1024. Astm c 1437 standard test method for flow of hydraulic. Wtf grout exceeds the corp of engineers specifications for non shrink grout crd c 621, all astm c 1107 requirements, and qualifies for 3 leed points always follow unisorb mixing in tructions. Meets astm c 1107 plastic and flowable packaged dry, hydraulic cement grout nonshrink noncorrosive, will not attack reinforcement nonshrink, per astm c 1107. This is the most common specification covering three grades of non shrink grout. Respectfully submitted, nelson testing laboratories mark r. Nonshrink, nonmetallic grout use sc precision grout is an ideal product for interior or exterior grouting of architectural and structural precast. Corps of engineers specification for non shrink grout. Non shrink groutfast set meets the requirements of astm c 1107 classification b for post set dimensional stability and the astm c 928 requirements for length change stability. Nonshrink oil and water resistant nonmetallic nonbleeding noncorrosive nonstaining structural te c h n i c a l da t a astm c1107.

The 1107 advantage grout is a non shrink, non metallic, non corrosive, cementitious grout that is designed to provide a controlled, positive expansion to ensure an excellent bearing area. Astm c 1107c 1107m08 standard specification for packaged ry. Crd c 621 grades a, b, c astm c 1107 grades a, b, c astm c 827 1107 advantage grout yielded a controlled positive expansion expansion astm c 1090. When properly mixed to a fluid consistency allows for pumping grout to areas where it is difficult to access using conventional grouting methods. Astm c 1107 c 1107m08 standard specification for packaged ry, hydrauliccement grout nonshrink pdf download this specification covers packaged dry, hydraulic cement grout nonshrink intended for use under applied load where a change in height below initial placement height is to be avoided. Features and benefits interiorexterior pumpable flowable high strength nonshrink noncorrosive nonmetallic meets corps of engineers specification crdc 621 meets or exceeds astm c1107 uses. The aggregate must be non reactive reference astm c 1260, c 227 and c 289, clean, well graded, saturated surface dry, have low absorption and high density, and comply with astm c 33 size number 8 per table 2.

Meets astm c1107 shows positive expansion when tested in accordance with astm c827 sikagrout is usdaapproved product information 50 lb. May be mixed to dry pack, plastic, flowable, and fluid consistencies for high versatility. Standard specification for packaged dry, hydrauliccement grout nonshrink. Astm c1107 analysis pagel usa v150 nonshrink grout. Fastset nonshrink grout used as a repair material are shown in table 2. Illinois modified astm c 1107c 1107m17 effective date. Sc multipurpose grout is a nonshrink, nonmetallic multipurpose cementbased grout. It is designed for a wide range of consistencies from damp pack to high fluidity, meeting the most demanding job conditions. Astm c1107, standard specification for packaged dry, hydraulic cement grout nonshrink. Nonshrink, nonmetallic structural hydraulic cement for high strength grouting of heavy machinery, steel bearing plates, concrete columns, etc. The 1107 advantage grout is a nonshrink, nonmetallic, noncorrosive, cementitious grout that is designed to provide a controlled, positive expansion to ensure an excellent bearing area.

Grout having metallic formulations or chlorides will not be allowed. October 5, 2018 standard method of test for packaged dry, hydrauliccement grout nonshrink modifications apply only when testing material according to article 1024. The aggregate must be nonreactive reference astm c1260, c227 and c289, clean, well graded, saturated surface dry, have low absorption and high density, and comply with astm c33 size number 8 per table 2. Precision non shrink construction grout is non shrink and non metallic. Passes astm c 1107, grade b or grade c, when tested at temperature placement minimums and maximums of 45 to 100 degree f. Astm c1107 standard test method for flow of hydraulic cement. A nonshrink, nonmetallic structural hydraulic cement for high strength grouting of heavy machinery, steel bearing plates, concrete columns, etc. Structural nonshrink nonmetallic highstrength cement. The euclid chemical company euclid solely and expressly warrants that its products shall be free from defects in materials and workmanship for one 1 year from the date of purchase. Masterflow 100 is a noncatalyzed hydraulic cementbased grout containing mineral aggregate. Sc multipurpose grout is a product in the nonmetallic grout category that meets astm c1107, crd. Dayton 1107 advantage grout 67435 fast shipping from. Five star grout meets the performance requirements of astm c 110702 grades a, b and c, astm c 110707, and crdc 62193 specifications for nonshrink grout over a wide temperature range, 40f 90f 4c 32c.

Sc multipurpose is formulated for a wide variety of grouting applications, from damp pack to flowable through a controlled, positive expansion. Consult the specific matrerial safety data sheets msds for all safety data. Sakrete nonshrink precision grout is a high strength, nonmetallic structural grout for anchoring machinery, bearing plates and more. Used for the exterior grouting of structural column base plates, pump and machinery bases, anchoring bolts, dowels, bearing pads and keyway joints. Prospec c1107 construction grout is a non shrink mixture of hydraulic cement, aggregate and additives. Astm c1107 99 standard specification for packaged dry. Shop undefined nonshrink construction grout 50lb concrete mix in the concrete mix department at lowe. Installation instructions for use as a grout mixing quikrete fastset non shrink grout should be mechanically mixed for a minimum of 3 minutes.

Non shrink, non metallic structural hydraulic cement for high strength grouting of heavy machinery, steel bearing plates, concrete columns, etc. Wtf grout exceeds the corp of engineers specifications for nonshrink grout crd c621, all astm c1107 requirements, and qualifies for 3 leed points always follow unisorb mixing in tructions. With the release of the 2005 edition of astm standards for concrete and aggregates, a revision was made to astm c 1107 the standard specification for packaged dry, hydrauliccement non shrink grout. A high performance, cementitious grout used for structural grouting of column base plates, machine base plates, anchor rods, bearing plates, etc. This specification covers packaged dry, hydraulic cement grout nonshrink intended for use under applied load where a change in height below initial placement. Use in a variety of applications where highstrength grouting is sakrete 50 lb. Bureau of materials packaged dry, hydrauliccement grout. Crdc621, corps of engineers specification for nonshrink grout astm c 1107, standard specification for packaged dry, hydrauliccement grout nonshrink canadian mtq appearance ns grout is a free flowing powder designed to be mixed with water. Astm c 1107, standard specification for packaged dry, hydrauliccement grout nonshrink warranty. Fastset non shrink grout used as a repair material are shown in table 2. Sc multipurpose grout is a non shrink, non metallic multipurpose cementbased grout. Compliances astm c 1107 test data property results test method compressive strength, psi mpa astm c 109, as modified by astm c 1107 consistency 1plastic 3flowable2 fluid 1 day 3,500 24.

Itw prc 100 is a high performance, nonshrink, precision grout that meets or exceeds all requirements of the corps of engineers crd c621 and astm c1107. Crdc 621 grades a, b, c astm c1107 grades a, b, c specification for nonshrink grout astm c827 1107 advantage grout yielded a controlled positive expansion test results. Sakrete nonshrink construction grout is a nonshrink, nonmetallic, structural hydraulic cement for highstrength grouting. Due to this change in astm c 1107, a specifier must include minimum and maximum. Prospec c1107 construction grout is a nonshrink mixture of hydraulic cement, aggregate and additives. Grout shall be tested at maximum water fluid consistency allowed by the manufacturer and remain fluid at temperature range minimums and maximums for 60 minutes after slight agitation. Use exterior grouting of structural column base plates. Volume control of grout is caused by expansion before hardening occurs. Provides a high strength, nonshrink grout for a broad range of general construction projects. Astm c1107 pdf 30 products find astm c products and abstract using the buildsite database.

This is the most common specification covering three grades of nonshrink grout. Volume control of grout is caused by expension after grout hardens. Specification for nonshrink grout grades a, b and c expansion astm c1090. Flow of grout for preplaced aggregate concrete flow cone method.

The 1107 advantage grout can be mixed from a fluid to a dry pack consistency. Provide prepackaged, nonshrink, cementitious grout that conforms to the following requirements. Non shrink groutfast set basalite concrete products. Standard specification for packaged dry, hydrauliccement.

1468 228 121 1098 173 1487 1205 279 220 840 500 119 1103 1215 682 509 308 1019 1050 338 921 968 864 740 1199 1054 535 1272 143 879 912